3aLaee a2686b7424 fix(mcu): escalate overtemp and watchdog-timeout faults to Emergency_Stop()
handleSystemError() only called Emergency_Stop() for error codes in
[ERROR_RF_PA_OVERCURRENT .. ERROR_POWER_SUPPLY] (9..13). Two critical
faults were left out of the gate and fell through to attemptErrorRecovery()'s
default log-and-continue branch:

  - ERROR_TEMPERATURE_HIGH (14): raised by checkSystemHealth() when the
    hottest of 8 PA thermal sensors exceeds 75 C. Without cutting bias
    (DAC CLR) and the PA 5V0/5V5/RFPA_VDD rails, the 10 W GaN QPA2962
    stages remain biased in an overtemperature state -- a thermal-runaway
    path in AERIS-10E.

  - ERROR_WATCHDOG_TIMEOUT (16): indicates the health-check loop has
    stalled (>60 s since last pass). Transmitter state is unknown;
    relying on IWDG to reset the MCU re-runs startup and re-energises
    the PA rails rather than latching the safe state.

Fix: extend the critical-error predicate so these two codes also trigger
Emergency_Stop(). Add test_gap3_overtemp_emergency_stop.c covering all
17 SystemError_t values (must-trigger and must-not-trigger), wired into
tests/Makefile alongside the existing gap-3 safety tests.