The ADAR1000 vector-modulator I/Q lookup tables VM_I[128] and VM_Q[128]
were declared but defined as empty initialiser lists since the first
commit (5fbe97f). Every call to adarSetRxPhase / adarSetTxPhase therefore
wrote (I=0x00, Q=0x00) to registers 0x21/0x23 (Rx) and 0x32/0x34 (Tx)
regardless of the requested phase state, leaving beam steering completely
non-functional in firmware.
This commit:
* Populates VM_I[128] and VM_Q[128] from ADAR1000 datasheet Rev. B
Tables 13-16 (p.34) on a uniform 2.8125 deg grid (360 / 128 states).
Byte format: bits[7:6] reserved 0, bit[5] polarity (1 = positive
lobe), bits[4:0] 5-bit unsigned magnitude - exactly as specified.
* Removes VM_GAIN[128] declaration and (empty) definition. The
ADAR1000 has no separate VM gain register; per-channel VGA gain is
set via CHx_RX_GAIN (0x10-0x13) / CHx_TX_GAIN (0x1C-0x1F) by
adarSetRxVgaGain / adarSetTxVgaGain. VM_GAIN was never populated,
never read anywhere in the firmware, and its presence falsely
suggested a missing scaling step in the signal path.
* Adds 9_Firmware/tests/cross_layer/adar1000_vm_reference.py: an
independently-derived ground-truth module containing the full
datasheet table plus byte-format / uniform-grid / quadrant-symmetry
/ cardinal-point invariant checkers and a tolerant C array parser.
* Adds TestTier2Adar1000VmTableGroundTruth (9 tests) to
test_cross_layer_contract.py, including a tokenising C/C++
comment+string stripper used by the VM_GAIN reintroduction guard,
and an adversarial self-test that corrupts one byte and asserts
the comparison detects it (defends against silent bypass via
future fixture/parser refactors).
Adversarially validated: removing the firmware definitions, flipping
a single byte, or reintroducing VM_GAIN as code each cause the suite
to fail; restoring causes it to pass. VM_GAIN appearing inside string
literals or comments correctly does NOT trip the guard.
Closes the empty-table half of the ADAR1000 phase-control bug class.
The separate channel-rotation issue (#90) will be addressed in a
follow-up PR.
Refs: 7_Components Datasheets and Application notes/ADAR1000.pdf
Rev. B Tables 13-16 p.34