Bug #1 — Range calibration for Raw IQ Replay:
- Add WaveformConfig dataclass (models.py) with FMCW waveform params
(fs, BW, T_chirp, fc) and methods to compute range/velocity resolution
- Add waveform parameter spinboxes to playback controls (dashboard.py)
- Auto-parse waveform params from ADI phaser filename convention
- Create replay-specific RadarSettings with correct calibration instead
of using FPGA defaults (781.25 m/bin → 0.334 m/bin for ADI phaser)
- Add 4 unit tests validating WaveformConfig math
Bug #2 — Demo + radar mutual exclusion:
- _start_demo() now refuses if radar is running (_running=True)
- _start_radar() stops demo first if _demo_mode is active
- Demo buttons disabled while radar/replay is running, re-enabled on stop
Bug #3 — Refactor adi_agc_analysis.py:
- Remove 60+ lines of duplicated AGC functions (signed_to_encoding,
encoding_to_signed, clamp_gain, apply_gain_shift)
- Import from v7.agc_sim canonical implementation
- Rewrite simulate_agc() to use process_agc_frame() in a loop
- Rewrite process_frame_rd() to use quantize_iq() from agc_sim